| 1. | TARIFF C1 - COMMERCIAL
|
RATE
PER UNIT
|
| For the first 100
units per month | 40
sen |
| For
the next 4900 units per month | 34
sen |
| For
each additional unit per month | 30
sen |
| Minimum
monthly charge | RM
10.00 |
| |
| 2. |
TARIFF C2 - COMMERCIAL DEMAND
|
RATE
PER UNIT
|
| For
each kilowatt of maximum demand per month | RM
16.00 |
| For
each unit | 25
sen |
| Minimum
monthly charge | RM
16.00 per
kilowatt X Billing Demand |
| |
| 3. | TARIFF C3
- COMMERCIAL PEAK/OFF-PEAK DEMAND |
RATE
PER UNIT
|
| For
each kilowatt of maximum demand per month during the peak
period
| RM
20.00
|
| For
each unit during the peak period
| 25
sen
|
| For
each unit during the off-peak period | 14.4
sen |
| Minimum
monthly charge | RM 20.00 per
kilowatt X Billing Demand |
| |
| 4. | TARIFF D -DOMESTIC |
RATE
PER UNIT |
| For the first 100
units per month | 34
sen |
| For
the next 300 units per month | 29
sen |
| For
each additional unit per month | 33
sen |
| Minimum
monthly charge | RM 5.00 |
| |
|
5. |
TARIFF I1 - INDUSTRIAL |
RATE
PER UNIT |
| For the first 100
units per month | 40
sen |
| For
the next 2900 units per month | 30
sen |
| For
each additional unit per month | 27
sen |
| Minimum
monthly charge | RM 10.00 |
| |
|
6. |
TARIFF I2 - INDUSTRIAL DEMAND |
RATE
PER UNIT |
| For
each kilowatt of maximum demand per month | RM
16.00 |
| For
each unit | 22.2
sen |
| Minimum
monthly charge | RM
16.00 per
kilowatt X Billing Demand |
| |
| 7. | TARIFF I3 - INDUSTRIAL PEAK/OFF-PEAK
DEMAND |
RATE
PER UNIT |
| For
each kilowatt of maximum demand per month during the peak
period
| RM
20.00
|
| For
each unit during the peak period
| 23.4
sen
|
| For
each unit during the off peak period | 14.4
sen |
| Minimum
monthly charge | RM 20.00 per
kilowatt X Billing Demand |
| |
| 8. | TARIFF PL - PUBLIC
& STREET LIGHTING |
RATE
PER UNIT |
| For
each unit | 47
sen |
| Minimum
monthly charge | RM 10.00 |
| LOWER
POWER
FACTOR PENALTY CHARGE |
| Consumers
shall use their best endeavors to obtain the highest Power
Factor possible in the operation of any of their
electrical installations. If the Average Power Factor in
any month is found to be:
a) Below 0.85 and up to
0.75 lagging, a supplementary charge of one and one-half
percent (1.5%) of the bill for that month for each
one-hundredth part (0.01) below 0.85 and up to 0.75
lagging Power Factor will be added to the bill for that
month, and
b) Below 0.75 lagging, in
addition to the charge payable under subparagraph (a)
above, a supplementary charge of three percent (3%) of the
bill for that month for each hundredth (0.01) part below
0.75 lagging Power Factor will be added to the bill for
that month. |
|
DEFINITIONS
Unless
the context otherwise states, the following definitions
shall apply: |
| "AVERAGE
POWER FACTOR" |
means
the cosine of the angle of which the tangent is obtained
by dividing the total of the reactive
kilovolt-ampere-hours by the total of the kilowatt-hours
recorded in any month by the company's meters. |
| "BILLING
DEMAND" |
measured
in kW means the maximum demand registered during the month
or seventy-five per cent (75%) of the maximum demand
registered during the preceding eleven (11) months or the
contract demand, whichever is higher; contract demand
being equal to the estimated demand at the meter point at
the time of connection. |
| "COMMERCIAL
SUPPLY" |
means
the supply of energy from the Company's supply lines to
all commercial premises including office block, shop,
godown, restaurant, school, hotel, boarding house, farms,
estate, port, broadcasting and telecommunication
installation, cinemas and entertainment locations,
military and Government installations and hospital, and
any supply used in the construction or building
activities, but excluding private dwellings and industrial
premises. |
| "DOMESTIC
SUPPLY" |
means
supply of energy to premises used only for private
dwelling purposes, provided that no commercial activity is
carried out in such premises.
|
| "INDUSTRIAL
SUPPLY" |
means
supply of energy to industrial operation such as
manufacturing, quarrying, mining, shipbuilding business,
and to consumers who utilize energy for the purpose of
pumping water, in whose premises electric motors and
plants are used in connection therewith and the total
wattage of lamps and air-conditionings installed for
purpose of office use shall not exceed twenty per cent
(20%) of the total wattage of all electric equipment
installed. |
| "MAXIMUM
DEMAND" |
means
measured in kW, twice the largest number of kilowatt-hours
supplied during any consecutive thirty minutes in any
month. |
| "MONTH" |
means
the period between two successive meter readings, meters
are normally read at intervals of approximately thirty
days. |
| "OFF-PEAK
PERIOD” |
means
the period between 0000 hours and 0700 hours. |
| "PEAK
PERIOD" |
means
the period between 0700 hours and 2400 hours. |
| "PUBLIC
LIGHTING SUPPLY" |
means
supply of energy to any legal entity including the
Commission of the City of
Kuching North
, Council of the City of
Kuching South
and other local authorities in respect of street lightings
and other general lighting purposes. |
| “SCHOOL” |
includes
kindergarten, children play school, nursery, tuition
centers, college and universities and any institutions
offering study courses of any nature.
|
Additonal information :